Unlock Free Global Shipping at $50
Ozone Analyzer UV | 0-50 ppm Range | 0.001 ppm Resolution | NIST Traceable (USA) | for Water Treatment, Air Quality Monitoring & Laboratory Testing
$2747.25
$4995
Safe 45%
Ozone Analyzer UV | 0-50 ppm Range | 0.001 ppm Resolution | NIST Traceable (USA) | for Water Treatment, Air Quality Monitoring & Laboratory Testing Ozone Analyzer UV | 0-50 ppm Range | 0.001 ppm Resolution | NIST Traceable (USA) | for Water Treatment, Air Quality Monitoring & Laboratory Testing Ozone Analyzer UV | 0-50 ppm Range | 0.001 ppm Resolution | NIST Traceable (USA) | for Water Treatment, Air Quality Monitoring & Laboratory Testing Ozone Analyzer UV | 0-50 ppm Range | 0.001 ppm Resolution | NIST Traceable (USA) | for Water Treatment, Air Quality Monitoring & Laboratory Testing
Ozone Analyzer UV | 0-50 ppm Range | 0.001 ppm Resolution | NIST Traceable (USA) | for Water Treatment, Air Quality Monitoring & Laboratory Testing
Ozone Analyzer UV | 0-50 ppm Range | 0.001 ppm Resolution | NIST Traceable (USA) | for Water Treatment, Air Quality Monitoring & Laboratory Testing
Ozone Analyzer UV | 0-50 ppm Range | 0.001 ppm Resolution | NIST Traceable (USA) | for Water Treatment, Air Quality Monitoring & Laboratory Testing
Ozone Analyzer UV | 0-50 ppm Range | 0.001 ppm Resolution | NIST Traceable (USA) | for Water Treatment, Air Quality Monitoring & Laboratory Testing
Ozone Analyzer UV | 0-50 ppm Range | 0.001 ppm Resolution | NIST Traceable (USA) | for Water Treatment, Air Quality Monitoring & Laboratory Testing
$2747.25
$4995
45% Off
Quantity:
Delivery & Return: Free shipping on all orders over $50
Estimated Delivery: 10-15 days international
6 people viewing this product right now!
SKU: 33564769
Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay
shop

Brand:FORENSICS DETECTORS
Model:FD-UVO3
YouTube:
User Manual:
Blog Article:

Features:

  • 馃寛聽 DISPLAY: High precision 0.001 ppm (1 ppb) resolution. Range of 0 - 50 ppm.聽
  • 馃敩 SUPERIOR: UV absorption 254 nm mercury lamp sensing technology produces the most accurate and precise ozone measurements.
  • 馃摬 COMMS:聽RS485 to USB enables computer calibration and data logging.
  • 馃挭 EASY: No buttons, just an ON/OFF switch. Comes in a waterproof travel carry case. No extra accessories are needed. NIST ozone traceable source calibration in Los Angeles, California.
  • 馃暤锔?TRUSTWORTHY: ** 1-year limited warranty ** Arrives with calibration and QA certificates ** Product tested and verified in the USA ** 100% quality guaranteed **

Details:聽One of the most advanced UV ozone analyzer on the market, small and easy to use. The ozone analyzer employs UV absorption sensing technology, using a 254 nm UV mercury lamp. Perfect for analytical applications such as research and development, experiments, ambient measurements, emissions, and process control. The instrument is calibrated at our Los Angeles laboratory with a NIST traceable source to ensure maximum accuracy of this ozone analyzer. The ozone analyzer has no buttons, just an ON/OFF switch for easy use. No complicated menus or setup is required. In addition, the device provides full control for advanced users via RS485 Modbus control. The analyzer is encased in a high-quality aluminum housing with a mountable front panel. Outside of yearly calibration to ensure peak performance, the instrument requires no maintenance.聽Please note that ozone is a unique gas and cannot be calibrated with a calibration gas bottle setup like most gase analyzers. Order yourwhich must be performed in our laboratory with special聽NIST calibrated equipment聽necessary to perform ozone gas detector calibration.聽

Included:聽FD-UV03 analyzer, power converter, RS485 to USB cable and connectors, waterproof travel carry case, T-piece, silicone tubing, user manual, and calibration certificate.

Specifications

  • UV Source:聽254 nm mercury lamp
  • Auto Range: auto selects between Range A聽& B
  • Range A:聽0 - 9.999 ppm, resolution: 0.001 ppm, error: +/- 0.05 ppm
  • Range B:聽10.00 - 50.00 ppm, resolution: 0.01 ppm, error: +/- 0.2 ppm
  • Outputs: digital LCD display. 0 - 5 V, 4 - 20 mA, RS485 Modbus
  • Error:聽see Range A and B or 2% of reading, whichever is higher
  • Sampling Time:聽10 seconds (adjustable)
  • Gas Sensor Type: Ultraviolet Gas Absorption Sensor Cell
  • Gas Sensor Life: 2-3 years
  • Recommended Calibration Period: 6-12 months
  • UV Lamp Warm-Up Time:聽10 minutes聽(startup time)
  • Operating Temperature:聽0 to 40C
  • Input Flow Rate:聽> 0.5 LPM
  • Inlet Air Connector:聽1/4 inch barb & 1/2 inch thread
  • Dimensions:聽4.75 in 脳 11.25 in 脳 3.60 in
  • Weight:聽2.0 kg (4.7 lb)
  • Power Requirement:聽24V DC at 1A (power converter included)
  • Calibration:聽12 months to maintain accuracy聽
  • Calibration Method: computer calibration via RS485 Modbus connection
  • Data Logging:聽via RS485 Modbus connection, saves to CVS text file
  • Warranty: one year
More

For all orders exceeding a value of 100USD shipping is offered for free.

Returns will be accepted for up to 10 days of Customer’s receipt or tracking number on unworn items. You, as a Customer, are obliged to inform us via email before you return the item.

Otherwise, standard shipping charges apply. Check out our delivery Terms & Conditions for more details.


You May Also Like

Top