Unlock Free Global Shipping at $50
Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants
$90.75
$165
Safe 45%
Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants
Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants
Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants
Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants
Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants
Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants
Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants
Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants
Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants
Hydrogen Gas Detector (H2 Sensor) - 0-1000 ppm Range for Industrial Safety & Leak Detection - Perfect for Laboratories, Fuel Cells & Chemical Plants
$90.75
$165
45% Off
Quantity:
Delivery & Return: Free shipping on all orders over $50
Estimated Delivery: 10-15 days international
25 people viewing this product right now!
SKU: 40172813
Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay
shop

Model:聽FD-H2-SENSOR
Datasheet:
Availability: 3 week lead time
Compatible: , , ,

Features

  • 鈿涳笍聽High precision and long life (2 years)
  • 馃殑 Fast response speed, fast return to zero聽
  • 馃攱 Low power consumption, high sensitivity
  • 馃敩Wide linear range, strong anti-interference ability
  • 馃挭 Excellent repeatability and stability

Description

These are generic H2 sensors used as the pin-to-pin replacement of the standard 4-series electrochemical sensors. It is used throughout many gas detector brands and is an excellent H2 gas sensor replacement element.

Our H2 electrolytic sensor operates by facilitating a reaction between hydrogen and oxygen at its working and counter electrodes. This electrochemical process generates an electric current directly proportional to the hydrogen concentration. By precisely measuring the resulting current, the sensor can accurately determine the hydrogen levels, providing a reliable method for hydrogen detection and quantification.

Our versatile H2 sensor finds critical applications across multiple domains, including industrial site monitoring, on-board hydrogen detection, municipal hydrogen management, and environmental protection. This advanced sensor technology enables precise hydrogen detection in diverse settings, ranging from industrial facilities to smart urban infrastructure. Its comprehensive capabilities support safety protocols, environmental monitoring, and technological advancements in hydrogen-related applications.

Instructions

  • Once replaced and installed in your gas detector or analyzer, please let it sit for24 hoursso the sensor can stabilize to your environment. This step is very important.
  • Then undertake the appropriate zero and calibration for your specific gas detector. See your gas detector manufacturer's specific instructions.
  • Once calibrated, your gas analyzer will be ready for use.

Specifications

Detection PrincipleElectrochemical Three Electrodes
Detection GasH2
Detection Range0-1000 PPM
Maximum Load Concentration2000 PPM
Output Signal20卤10 nA/PPM
Zero Drift卤1 PPM
Resolution1 PPM
Response Time<60s
Bias Voltage0
Load Resistance5~30惟
Working Temperature-30鈩?to 50鈩?/td>
Working Humidity15%RH to 90%RH (no condensation)
Repeatability<卤2% output signal
Long-term Stability<2% signal/month
LinearityLinearity 2000 PPM
Work Pressure90 to 110 kPa
Shelf Life12 months after delivery
Service Life2 years

Cross-Sensitivity Data

Interfering GasGas Concentration Used (ppm)Value Displayed (ppm H2)
CO50150
SO2200
H2S1000
CL2101
NO309
NO2201
CH45000-2
More

For all orders exceeding a value of 100USD shipping is offered for free.

Returns will be accepted for up to 10 days of Customer’s receipt or tracking number on unworn items. You, as a Customer, are obliged to inform us via email before you return the item.

Otherwise, standard shipping charges apply. Check out our delivery Terms & Conditions for more details.


You May Also Like

Top