Unlock Free Global Shipping at $50
Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use
$90.75
$165
Safe 45%
Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use
Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use
Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use
Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use
Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use
Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use
Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use
Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use
Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use
Chlorine Sensor (Cl2) | 0-50 ppm Range | Water Quality Monitoring for Pools, Drinking Water & Industrial Use
$90.75
$165
45% Off
Quantity:
Delivery & Return: Free shipping on all orders over $50
Estimated Delivery: 10-15 days international
23 people viewing this product right now!
SKU: 59925013
Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay
shop

Model:聽FD-Cl2-SENSOR
Datasheet:聽
Availability:
3 week lead time
Compatible: , ,

Features

  • 鈿涳笍聽High precision and long life (2 years)
  • 馃殑 Fast response speed, fast return to zero
  • 馃攱 Low power consumption, high sensitivity
  • 馃敩Wide linear range, strong anti-interference ability
  • 馃挭 Excellent repeatability and stability

Description

These are generic Cl2 sensors used as the pin-to-pin replacement of the standard 4-series electrochemical sensors. It is used throughout many gas detector brands and is an excellent Cl2 gas sensor replacement element.

Our CL2 chlorine gas detection sensor employs an innovative electrolytic mechanism to measure gas concentrations. Through an electrochemical process, chlorine and oxygen undergo oxidation-reduction reactions on specialized electrodes, generating an electrical current directly proportional to the chlorine gas concentration. By precisely measuring this current, the sensor provides accurate and reliable detection of chlorine levels, enabling critical safety monitoring in industrial and environmental applications.

Our CL2 chlorine gas sensor finds extensive applications across diverse sectors, including industrial sites, municipal water treatment facilities, and environmental monitoring. It plays a crucial role in detecting chlorine concentrations in industrial settings, animal husbandry environments, and atmospheric conditions. This versatile sensor provides comprehensive chlorine detection capabilities, ensuring safety, environmental monitoring, and regulatory compliance across multiple professional and scientific domains.

Instructions

  • Once replaced and installed in your gas detector or analyzer, please let it sit for24 hoursso the sensor can stabilize to your environment. This step is very important.
  • Then undertake the appropriate zero and calibration for your specific gas detector. See your gas detector manufacturer's specific instructions.
  • Once calibrated, your gas analyzer will be ready for use.

Specifications

Detection PrincipleElectrochemical Three Electrodes
Detection GasCL2
Detection Range0-50 PPM
Maximum Load Concentration100 PPM
Output Signal-450卤150 nA/PPM
Zero Drift0~0.2 PPM
Resolution0.1 PPM
Response Time<60s
Bias Voltage0
Load Resistance5~30惟
Working Temperature-30鈩?50鈩?/td>
Working Humidity15%RH to 90%RH (no condensation)
Repeatability<卤2% output signal
Long-term Stability<2% signal/month
LinearityRegression coefficient R虏 = 0.999
Work Pressure90 to 110 kPa
Shelf Life12 months after delivery
Service Life2 years

Cross-Sensitivity Data

Interfering GasGas Concentration Used (ppm)Value Displayed (ppm CL2)
CO1000
H2S250
H210000
NO309
NO2200
SO2200
NH3201
CH45000-2
More

For all orders exceeding a value of 100USD shipping is offered for free.

Returns will be accepted for up to 10 days of Customer’s receipt or tracking number on unworn items. You, as a Customer, are obliged to inform us via email before you return the item.

Otherwise, standard shipping charges apply. Check out our delivery Terms & Conditions for more details.


You May Also Like

Top